Welcome, Guest. Please Login or Register
MyECU main site
  Welcome to our forum.
  HomeHelpSearchLoginRegister  
 
Page Index Toggle Pages: 1
Send Topic Print
Correcting a past error - Missing pulses (Read 850 times)
YaBB Administrator
YaBB Administrator
*****
Offline


I love YaBB!

Posts: 676
The Land of YaBB
Correcting a past error - Missing pulses
03/08/22 at 18:27:00
 
Those with a My16M or My15M will have the following configuration in their map.
# TDC is the pulse count for TDC power stroke of cylinder 1 ( i.e. When the spark fires
# CylOffs is the number of degrees between success cylinders ( 0-720)
# PulsesPer is the number of pulses for the 720 degree 4 stroke cycle

MyECU Cfg TDC=0x1600, CylOffs=270, PulsesPer=48, MissingPulses=3

The value of 3 for missing pulses was due to some early confusion on my part (2 missing teeth gives a gap period 3 times greater). The correct value should be 2.
This error has not caused any issues, being cosmetic and embarrassing only but should be corrected to avoid issues with future versions of the firmware.
Back to top
« Last Edit: 03/10/22 at 07:06:28 by YaBB Administrator »  

The Administrator.
WWW  
IP Logged
 
sign216
Full Member
***
Offline



Posts: 175
Re: Correcting a past error
Reply #1 - 03/09/22 at 11:20:56
 
Admin,

Thanks for the update.  So the old value doesn't adversely affect performance, but the new value is more correct. 

Is that the best way to put it?

Joe
Back to top
 
 
IP Logged
 
YaBB Administrator
YaBB Administrator
*****
Offline


I love YaBB!

Posts: 676
The Land of YaBB
Re: Correcting a past error
Reply #2 - 03/09/22 at 12:55:19
 
Well not more correct, just correct. The old value was wrong but had no effect on operation at all.
Back to top
 

The Administrator.
WWW  
IP Logged
 
Page Index Toggle Pages: 1